R-GUARD INSTALLATION GUIDELINES

Download Printable Version

SHEATHING WALL CONSTRUCTION

sheathing wall seam preview

Sheathing Wall Seam
S1.1 
pdf   cad

Inside-Outside Wall Corners

Inside/Outside Wall Corners 
S2.1
pdf   cad

Pipe and Mechanical Penetrations S3.1

Pipe and Mechanical Penetrations 
S3.1
pdf   cad

Rough Opening on Sheathing Wall One Product S4.1A

Rough Opening on Sheathing Wall One Product
S4.1A
pdf   cad

Rough Opening on Sheathing Wall Two Products S4.1B

Rough Opening on Sheathing Wall Two Products
S4.1B
pdf   cad

Window Head Flashing S5.1

Window Head Flashing
S5.1
pdf   cad

Sealing Window Flanges S6.1

Sealing Window Flanges
S6.1
pdf   cad

Interior Air and Water Seal S7.1

Interior Air and Water Seal
S7.1
pdf   cad

Roof-To-Wall Transition - Parapet Wall Face S8.1

Roof-To-Wall Transition - Parapet Wall Face
S8.1
pdf   cad

Roof-To-Wall Transition - Wall Cap to Roof S9.1

Roof-To-Wall Transition - Wall Cap to Roof
S9.1
pdf   cad

Termination at Grade – Stucco S10.1

Termination at Grade – Stucco
S10.1
pdf   cad

Rough Opening Integration with Building Wrap S11.1

Rough Opening Integration with Building Wrap
S11.1
pdf   cad

Deflection joint 1 Inch and Smaller S12.1A

Deflection joint 1 Inch and Smaller
S12.1A
pdf   cad

Deflection joint greater than 1 Inch S12.1B

Deflection joint greater than 1 Inch
S12.1B
pdf   cad

Deflection joint Corner Condition Greater than 1 Inch S12.1C

Deflection joint Corner Condition Greater than 1 Inch
S12.1C
pdf   cad

Rough Opening with FastFlash and building Wrap S13.1

Rough Opening with FastFlash and Building Wrap
S13.1
pdf   cad

Vertical Expansion joint S14.1

Vertical Expansion joint
S14.1
pdf   cad

Vertical Expansion at Disimilar Substrate 1” wide S14.2

Vertical Expansion at Disimilar Substrate> 1” Wide
S14.2
pdf   cad

Overlap-Splice Joint of SureSpan EX S14.3

Overlap/Splice Joint of SureSpan EX
S14.3
pdf   cad

Corner Overlap-Butt Joint of SureSpan EX S14.4

Corner Overlap/Butt Joint of SureSpan EX
S14.4
pdf   cad

Joint Intersection SureSpan EX S14.5

Joint Intersection SureSpan EX
S14.5
pdf   cad

CMU WALL CONSTRUCTION

 

cmu-cip-concrete-rough-opening-c11

CMU/CIP Concrete Rough Opening
C1.1
pdf   cad

pipe-and-mechanical-penetrations-c21

Pipe and Mechanical Penetrations
C2.1
pdf   cad

wall-to-roof-transition-parapet-to-roof-plane-c31

Wall-to-Roof Transition - Parapet to Roof Plane
C3.1
pdf   cad

cmu-cip-concrete-arched-window-rough-opening-c41

CMU/CIP Concrete Arched Window Rough Opening
C4.1
pdf   cad

interior-air-and-water-seal-c51

Interior Air and Water Seal
C5.1
pdf   cad

sliding-glass-door-c61

Sliding Glass Door
C6.1
pdf   cad

SS THRU WALL FLASHING

Flashing Corner Units and End Dams F1.1

Flashing Corner Units and End Dams
F1.1
pdf   cad

inside-outside-corner-detail-f11a

Outside Corner Detail
F1.1A
pdf   cad

inside-corner-detail-f11b

Inside Corner Detail
F1.1B
pdf   cad

SS Thru Wall Accessories F1.1C

SS Thru Wall Accessories
F1.1C
pdf

Flashing Transition - Base of Wall F2.1

Flashing Transition - Base of Wall
F2.1
pdf   cad

Flashing Transition – Shelf Angle with Termination Bar F3.1

Flashing Transition – Shelf Angle with Termination Bar
F3.1
pdf   cad

window-head-detail-ss-thru-wall-flashing-termination-bar

Window Head Detail SS Thru Wall Flashing & Termination Bar
F4.1
pdf   cad