By Alex Boyer

As demand for carbon-conscious building and design increases, designers are becoming more diligent in evaluating strategies for limiting carbon in our buildings. Some owners want the design to focus on embodied carbon, focusing on using low-carbon and even carbon-sequestering materials. Others may focus on limiting operational carbon by employing tactics to maximize energy efficiency post-occupation.
But as the green building movement evolves, the industry is accepting that a more holistic view of carbon accounting is necessary. Green buildings today require complicated modeling and balancing of the embodied carbon of building materials and the long-term energy efficiency of the building.
Follow the data
Data centers are a great example of this balancing act. It’s no secret that data center projects face headwinds. The political environment surrounding these projects can be tenuous at best. But, AI companies need more bandwidth and processing power for their newest models and products. They have to build more data centers and they want to build them fast.
In order to meet the concerns of the communities where they are building, data center developers are targeting green building standards such as LEED. Combining their demands on the electrical grid with exacting performance requirements equals the need for extremely discerning material selection. Because data center developers are under increasing pressure to demonstrate environmental responsibility, reduce emissions, and build efficient facilities, this makes a data center a unique proving ground for a more holistic approach to carbon accounting – one that considers the emissions associated with constructing a building and those associated with operating it.
They encapsulate the idea that embodied carbon and operational carbon are not competing priorities. They are two parts of the same building performance equation.
Start with the full carbon picture
Embodied carbon encompasses the greenhouse gas emissions associated with building materials and their life cycles, including raw material extraction, manufacturing, transportation, installation, maintenance, replacement, and end-of-life treatment, depending on the boundaries of a given calculation.
On the other hand, operational carbon is the energy and operations processes required for the building to serve its designed function and use. Electricity used for cooling, ventilation, lighting, equipment, and other mechanical systems can make a substantial contribution to a building’s lifetime emissions.
Each category of this carbon calculation requires its own strategy.
When it comes to materials, project teams may choose a lower-carbon concrete mix design, such as a Portland Cement Limestone, also called Type 1L or a Blended Hydraulic Cement, which uses uncooked or raw limestone to reduce the volume cement clinker necessary to maintain the strength of cured concrete. This limits the embodied carbon of the concrete because the clinker requires kilning, requiring significant energy use. They may specify mass timber, which, as long as it’s forested sustainably, is considered carbon-sequestering. Carbon sequestration is the process of capturing carbon from the environment, and carbon-sequestering materials use the carbon from the atmosphere in our buildings. Other materials may lower your embodied carbon due to their recycled contents or capacity for reuse.
When it comes to operational carbon, that may mean improvements in energy efficiency, optimized mechanical systems like an energy-recovering HVAC system and alternative energy sources.
More than one lever
Instead of a single material-selection strategy, project teams have more than one lever to pull in front of them. Consider two enclosure designs: One option may have a lower initial embodied carbon footprint, while the second may offer better air barrier continuity, more reliable moisture management, or greater long-term durability. If the lower-carbon option compromises the performance of the enclosure, the initial carbon savings of materials may not represent the best whole-building outcome.
Embodied carbon is not to be dismissed, but rather, quantified alongside the performance characteristics affecting the building’s operations and service life.
Air leakage can undermine intended thermal performance and introduce moisture risks. A continuous, well-executed air barrier helps limit uncontrolled air movement, while properly designed and installed water-resistive barriers and flashing details help manage bulk water.
These functions are not interchangeable, and an effective envelope depends, again, on the entire assembly, including transitions, penetrations, joints, and interfaces between materials. Reducing emissions while ensuring performance targets are met requires coordination between everyone on the team, including architects, engineers, consultants, and contractors.
"...an EPD replaces an unsupported environmental claim with documented information."
Proof over claims
Environmental Product Declarations (EPDs) provide a standard way to communicate the environmental impacts of building products over defined life-cycle stages. Typically developed through a life-cycle assessment, EPDs give design teams quantified information they need for embodied-carbon accounting.
For designers, the value of an EPD is that it replaces an unsupported environmental claim with documented information.
An EPD is not, by itself, a declaration that a product is low-carbon. Rather, it reports environmental impacts according to a defined methodology and scope. Some EPDs cover a broader range of life-cycle stages than others, and results can only be compared responsibly when the underlying methodologies, functional or declared units, system boundaries, and other relevant assumptions are consistent.
An EPD may report global warming potential (GWP), commonly expressed in kilograms of carbon dioxide equivalent (kg CO2e), along with other environmental indicators. Designers can use the reported GWP to help estimate a product’s contribution to the project’s embodied carbon.
The calculation is:
Product embodied carbon = quantity of product x reported GWP per unit
A product’s declared unit might be based on mass, area, volume, or another quantity. Before multiplying, the project team should ensure that its takeoff matches the EPD’s declared unit.
For a data center, that process may involve thousands of individual material quantities across structural systems, the enclosure, interiors, and site work. EPDs provide one of the essential inputs for building a defensible embodied-carbon profile.
The resulting analysis can help identify high-impact materials, compare appropriate alternatives, establish targets and document progress toward carbon goals.
EPDs -> embodied carbon calculations
Address carbon accounting before major specifications and purchasing decisions are locked in. First, establish a baseline. Develop an inventory (that’s as close to complete as possible) of materials with the project’s quantities, units, and available environmental data. Identify materials and assemblies likely to have the greatest impact on embodied carbon.
Then, decisions should be prioritized by impact and feasibility. Concrete, steel, and other high-volume materials warrant signification attention, but enclosure materials should not be overlooked just because they represent a smaller share of total building mass. Their impacts belong in the calculation, and their performance affects long-term durability and building operations.
Next, evaluate products with consistent data. Request EPDs from manufacturers, verify the declarations apply to your specified products, and confirm declared units and life-cycle boundaries match the project’s accounting methods. When product-specific EPDs are unavailable, use appropriate industry-average data and document assumptions.
Finally, track the results as the design develops. A carbon model is only as useful as its relationship to the building’s design and construction in real life. Quantities changed? Substitution requests? Make adjustments accordingly while maintaining a record of assumptions and updates to keep the team in step with the goal.
Going for LEED v5? You’re aligned. With a greater emphasis on measurable decarbonization, including the assessment and reduction of embodied carbon, LEED v5’s Building Design and Construction framework includes approaches for whole-building life-cycle assessment and EPD-based analysis.
An EPD does not automatically earn a certification credit, and the presence of an EPD does not guarantee that a product has lower embodied carbon than an alternative. Certification depends on the team’s work of following the rating system requirements and evaluating the relevant data.
The other side of the equation
But a building’s carbon output does not stop at embodied carbon. The building operational carbon is incredibly important to evaluate and model at the design phase. Operational emissions account for 27% of global emissions. While most of this is a result of older, less efficient buildings, it is important that project teams consider energy efficiency strategies alongside embodied carbon reduction.
Operational carbon is much more difficult to model than embodied carbon. A building’s operational efficiency can change over time. As a building is used it may degrade, increasing operational carbon output. But grid decarbonization may improve a building’s operational carbon output.
It’s important that both operational and embodied decarbonization strategies work together. Most strategies are complimentary, but some are not. Increasing insulation or using high-performance windows with thicker glass may add significant embodied carbon but limit operational carbon. Design teams have to find a balance that works for their project.
The envelope is critical
Some strategies can improve both sides of the carbon equation at once. The clearest example of this is airtightness. HVAC in occupied buildings is the single largest operational carbon load and can account for up to half of a building’s total operational carbon output. Any conditioned air leaking out of the building or unconditioned air leaking in adds directly to that load.
Design teams can find significant operational carbon decreases with negligible embodied carbon increases by designing tight building envelopes. Fluid-applied air and water barriers may not seem like a necessity if you’re just trying to create the lowest embodied carbon building possible, but once you bring operational carbon into the equation, they’re invaluable.
New EPDs bring R-Guard into focus
At PROSOCO, we hope that designers recognize our brand as one that has been committed to designers’ sustainability efforts and goals for decades.
The R-Guard line of air and water barrier products has long been trusted on the greenest buildings in the world, including the Bullitt Center, the Kendeda Building at Georgia Tech, and hundreds of others that meet standards like net-zero, Passive House, Living Building Challenge, and on and on. We’ve always been conscious about the manufacturing impact of our products on the environment, and we now have documentation of that impact with six EPDs for R-Guard air and water barrier products.
The six newly published EPDs cover FastFlash, AirDam, Joint & Seam Filler, Cat 5, Cat 5 Rain Screen, and Targeted Interior Air Seal. They provide cradle-to-gate environmental impact documentation, giving project teams the data needed to complete their material assessments and carbon calculations.
Each product serves a specific function within the broader enclosure. FastFlash is a fluid-applied flashing membranes for rough openings; AirDam is an air- and weather-barrier sealant that goes around installed windows and doors; Joint & Seam Filler is a fiber-reinforced filler for seams, pinholes and joints; Cat 5 is a water-resistive barrier for the field of the wall; Cat 5 Rain Screen is a WRB for rain screen applications; and Targeted Interior Air Seal air-seals envelopes from building interiors, including around through-wall penetrations and at joints separating conditioned from non-conditioned spaces.
These EPDs do not eliminate the need to evaluate product suitability, assembly design, installation quality, or long-term performance. Rather, they are intended to add another piece of information to your evaluation – documented environmental impacts that can be considered alongside technical specifications.
For existing buildings, the inclusion of Targeted Interior Air Seal in our library of EPDs is relevant – many people think of new construction when they think of green building, but existing buildings are quite green, as the saying goes, and they also need a good quality air seal from the interior. We’re excited to get this accreditation for TIAS to show that it can and should be used in LEED and green building-certified retrofits moving forward.
New or existing, our goal is to make the environmental impacts of these products more transparent while continuing to support the enclosure performance designers and building owners have come to expect from PROSOCO R-Guard.
Better questions -> better accounting
The next generation of sustainable buildings will not be defined by a single material, certification or carbon metric. It will be defined by how effectively project teams coordinate material selection, building science, energy performance, durability, and environmental accountability.
Data centers make the stakes particularly visible, but the underlying principle applies across commercial construction. Whether the goal is reduced embodied carbon or operational emissions, neither objective should be pursued in isolation. They should be included in pursuit of a wholesale understanding of a building’s environmental impact. When we account for the materials we use and design those materials into assemblies that perform as intended, we give ourselves the best opportunity to reduce carbon across the life of the building.
![]()