R-Guard Installation Detail
Open Joint one Inch and Smaller
wood construction with plywood/OSB sheathing
1.
Limit the size of the deflection joint to no more than 1 inch in width for FastFlash use. Reference 12.4 for deflection joints greater than 1 inch.
2.
Install non-gassing polyethylene foam backer rod into joint opening in preparation to receive Joint & Seam Filler. Apply Joint & Seam Filler into opening, over-filling the joint to provide enough material to tool excess on both sides of the joint, about 1 inch on either side.
3.
After Joint & Seam Filler has skinned over, apply a 4-inch-wide application of FastFlash banding over the Joint & Seam Filler in a bridge-joint configuration.
4.
After FastFlash has skinned over, apply the selected PROSOCO Primary Air & Water Resistive Barrier over entire joint.