R-Guard Installation Detail
Sheathing Wall Seam
with metal studs with gypsum sheathing/OSB sheathing/plywood
1.
Spot over all fasteners with FastFlash or Joint & Seam Filler.
2.
Apply a thick bead of FastFlash or Joint & Seam Filler to all sheathing joints.
3.
Use a dry joint knife or trowel to spread 1 inch beyond the seam on each side to a minimum thickness of 12 mils (FastFlash) or 20 mils (Joint & seam Filler).
4.
Follow sheathing manufacturer recommendations to repair joints or gaps greater than 1 inch.
5.
Apply the selected PROSOCO primary air and water-resistive barrier over the prepared sheathing wall.
READY TO HELP